{"id":1106,"date":"2023-02-17T02:30:48","date_gmt":"2023-02-17T02:30:48","guid":{"rendered":"https:\/\/www.airpressureswitch.com\/?post_type=product&#038;p=1106"},"modified":"2023-02-23T01:35:10","modified_gmt":"2023-02-23T01:35:10","slug":"wasserstandssensor","status":"publish","type":"product","link":"https:\/\/www.airpressureswitch.com\/de\/product\/water-level-sensor","title":{"rendered":"Wasserstandssensor f\u00fcr Geschirrsp\u00fcler, 72 mA, 5 V DC"},"content":{"rendered":"<h2>C4-A Washer Water Level Sensor<\/h2>\n<p><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"0\" data-group=\"0-0\">This fully automatic wave washer water level sensor is mainly used in the washing machine market where multiple water levels are needed.<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"1\" data-group=\"0-1\"> The C4-A water level sensor is specially designed for applications where precise tolerances are still required over a wide temperature range.<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"2\" data-group=\"0-2\"> Meanwhile, our C4-A water level sensor is used not only in washing machines but also in dishwashers to detect water levels.<\/span><\/p>\n<p><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"0\" data-group=\"0-0\">\u00a0A water level sensor it uses the air pressure generated in the process of water level rise to transmit the water level signal. When the washing machine controller receives the signal, it will start to calculate, and then issue the working order to the water electric valve according to the calculated data.<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"1\" data-group=\"0-1\"> This part is very important for the washing machine. If this part is damaged, it will appear inaccurate water injection or not work.<\/span><\/p>\n<h3>Water Pressure Switch Dishwasher Main Parameters<\/h3>\n<p><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"0\" data-group=\"0-0\">The water level sensor acts as a <a href=\"https:\/\/www.airpressureswitch.com\/de\/produkte\/\">Druckschalter<\/a>.<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"1\" data-group=\"0-1\"> When you set a pressure value, water is injected to produce <a href=\"https:\/\/www.airpressureswitch.com\/de\/produkte\/\">water pressure<\/a>, and when the pressure value is reached, electricity is automatically applied.<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"2\" data-group=\"0-2\"> Reach the switch function washing machine water level switch is divided into electronic (adjustable resistance) and switch type two, they are through the water level rise produced by the air pressure through the pipeline to the sensor to change the resistance or the internal switch on to make the computer action, it will be damaged after water injection is not allowed, long water injection does not move (operation),<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"3\" data-group=\"0-3\"> Drain the water without draining it (this is rare because the sensor is out of position).<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"4\" data-group=\"0-4\"> During maintenance, attention should be paid to checking whether the pipeline is broken, whether the seal is good at both ends, and whether the sensor is leaky. When checking the sensor, the air can be blown into the air by the mouth from the air inlet at the same time, and whether the resistance value at both ends of the sensor is changed or whether the switch is connected. The screw above the switch-type sensor is used to adjust the level of water injection.<\/span><\/p>\n<figure id=\"attachment_1120\" aria-describedby=\"caption-attachment-1120\" style=\"width: 800px\" class=\"wp-caption aligncenter\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-1120\" src=\"https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2023\/02\/C4-characteristic-curve-1.jpg\" alt=\"C4-characteristic-curve\" width=\"800\" height=\"344\" srcset=\"https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2023\/02\/C4-characteristic-curve-1.jpg 800w, https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2023\/02\/C4-characteristic-curve-1-300x129.jpg 300w, https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2023\/02\/C4-characteristic-curve-1-768x330.jpg 768w, https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2023\/02\/C4-characteristic-curve-1-600x258.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><figcaption id=\"caption-attachment-1120\" class=\"wp-caption-text\">C4-characteristic-curve<\/figcaption><\/figure>\n<h3>C4-A Water Level Pressure Sensor Specification<\/h3>\n<table style=\"height: 411px;\" border=\"1\" width=\"1361\" cellpadding=\"6\">\n<tbody>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt; width: 140.25pt;\" width=\"187\" height=\"19\">Modellnummer<\/td>\n<td style=\"width: 279.75pt;\" width=\"373\">C4-A Water Level Pressure Sensor<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt; width: 140.25pt;\" width=\"187\" height=\"19\">Stromspannung<\/td>\n<td style=\"width: 279.75pt;\" width=\"373\">DC5V\u00b12%<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt; width: 140.25pt;\" width=\"187\" height=\"19\">Toleranz gegen\u00fcber dem Wasserstand<\/td>\n<td style=\"width: 279.75pt;\" width=\"373\">Min. +\/-5 mmWC, Standard +\/-10 mmWC<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Wasserstandsbereich\/Frequenz<\/td>\n<td>0~325 mmWC \/ 26~21,4 (kHz)<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Zul\u00e4ssiger Druck<\/td>\n<td>Max. 760 mmWC<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Betriebstemperatur<\/td>\n<td>0~50\u00b0C (T50)<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Umgebungsfeuchtigkeit<\/td>\n<td>95% relative Luftfeuchtigkeit Max.<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Zul\u00e4ssiger Strom<\/td>\n<td>72 mA Max.<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Schnittstellengr\u00f6\u00dfe<\/td>\n<td>Au\u00dfendurchmesser: 5,5 mm<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Arbeitsmedium<\/td>\n<td>Luft<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Montageanleitung<\/td>\n<td>Die Membran ist in einer horizontalen Ebene installiert, und die Druckschnittstelle befindet sich unterhalb<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Membran<\/td>\n<td>Silikon<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Geh\u00e4usematerial<\/td>\n<td>PP+GF, <a href=\"https:\/\/en.wikipedia.org\/wiki\/UL_94\" target=\"_blank\" rel=\"noopener\">UL94 V-2<\/a><\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Spulenformer<\/td>\n<td>PA66+GF, GWIT&gt;650\u00b0C<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Nutzungsdauer<\/td>\n<td>50000 Zyklen<\/td>\n<\/tr>\n<\/tbody>\n<\/table>","protected":false},"excerpt":{"rendered":"<p>C4-A water level sensor is mainly used in the washing machine market which needs multiple water level selections, widely used in washing machines and dishwashers, used to detect the level of water.<\/p>\n<h2>Wasserstandssensor<\/h2>","protected":false},"featured_media":1108,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[33],"product_tag":[],"class_list":{"0":"post-1106","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-water-level-sensor","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/product\/1106","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/comments?post=1106"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/media\/1108"}],"wp:attachment":[{"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/media?parent=1106"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/product_brand?post=1106"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/product_cat?post=1106"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/product_tag?post=1106"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}