{"id":990,"date":"2023-01-04T03:29:12","date_gmt":"2023-01-04T03:29:12","guid":{"rendered":"https:\/\/www.airpressureswitch.com\/?post_type=product&#038;p=990"},"modified":"2023-01-04T03:30:41","modified_gmt":"2023-01-04T03:30:41","slug":"differential-pressure-switch-for-air-filter","status":"publish","type":"product","link":"https:\/\/www.airpressureswitch.com\/de\/product\/differential-pressure-switch-for-air-filter","title":{"rendered":"A411 Differential Pressure Switch for Air Filter VAV System"},"content":{"rendered":"<h3>Differential Pressure Switch for Air Filter Description<\/h3>\n<p>The A411 is a differential pressure switch for air filter systems, VAV systems, water heaters, wall-hanging boilers, etc. that is available for custom pressure points. The appearance of the A411 belongs to the forward terminal type, which is the SPST normally open circuit.<\/p>\n<p>The terminal type or direction is designed for that you can install it easily if you have another requirement, please contact us or <a href=\"https:\/\/www.airpressureswitch.com\/de\/luftdruckschalter\/\">visit the REGAL Air pressure switches<\/a> page to see more.<\/p>\n<p>Meanwhile, the differential pressure switch for air filter has 2 differential pressure ports, one is the high pressure and another one is the low-pressure port. In the application, it needs to connect according to the design of the product, please contact us for more details.<\/p>\n<p>Unlike the traditional <a href=\"https:\/\/www.grandye-switch.com\/product\/16a-125v-air-pressure-switch-for-pellet-stove-application\/\" target=\"_blank\" rel=\"noopener\">microswitch type air pressure switch<\/a>, our switch not only uses the integrated design but also has our own letters patent. This design has a wider working pressure range, higher accuracy, longer working life, and so on. For more <a href=\"https:\/\/www.airpressureswitch.com\/de\/produkte\/\">pressure switch &amp; pressure sensor products<\/a>, please click the link to see more.<\/p>\n<p>&nbsp;<\/p>\n<h4><strong>A411 Differential Pressure Switch for Air Filter Size<\/strong><\/h4>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-952\" src=\"https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2022\/12\/A4-Air-pressure-switch.jpg\" alt=\"A4 Air pressure switch size\" width=\"800\" height=\"357\" srcset=\"https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2022\/12\/A4-Air-pressure-switch.jpg 800w, https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2022\/12\/A4-Air-pressure-switch-300x134.jpg 300w, https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2022\/12\/A4-Air-pressure-switch-768x343.jpg 768w, https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2022\/12\/A4-Air-pressure-switch-600x268.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<h3>Differential Pressure Switch for Air Filter Specification<\/h3>\n<table style=\"height: 411px;\" border=\"1\" width=\"1361\" cellpadding=\"6\">\n<tbody>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt; width: 140.25pt;\" width=\"187\" height=\"19\">Modellnummer<\/td>\n<td style=\"width: 279.75pt;\" width=\"373\">A411<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt; width: 140.25pt;\" width=\"187\" height=\"19\">Arbeitsmedium<\/td>\n<td style=\"width: 279.75pt;\" width=\"373\">Air or Tail gas<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt; width: 140.25pt;\" width=\"187\" height=\"19\">Terminal Types<\/td>\n<td style=\"width: 279.75pt;\" width=\"373\">Standard 187 Quick Connect (4.8*0.5mm)<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Rohrschnittstelle<\/td>\n<td>6,3 mm Au\u00dfendurchmesser, passend f\u00fcr ein Rohr mit 5 mm Innendurchmesser<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Schaltung<\/td>\n<td>SPST NO<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Bewertung<\/td>\n<td>1A\u00a0 24VDC &amp; 0.5A 125\/250VAC<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Withstand Voltage<\/td>\n<td>3000Pa(0.5Psi)<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Elektrische Lebensdauer<\/td>\n<td>25000000 cycles<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Gas recovery outlet<\/td>\n<td>Negative<\/td>\n<\/tr>\n<tr style=\"height: 14.25pt;\">\n<td style=\"height: 14.25pt;\" height=\"19\">Betriebstemperatur<\/td>\n<td>-40 to +110\u2103<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img decoding=\"async\" class=\"size-full wp-image-992\" src=\"https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2023\/01\/A411-Differential-Pressure-Switch-for-Air-Filter-Specification.jpg\" alt=\"A411 Differential Pressure Switch for Air Filter Specification\" width=\"800\" height=\"330\" srcset=\"https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2023\/01\/A411-Differential-Pressure-Switch-for-Air-Filter-Specification.jpg 800w, https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2023\/01\/A411-Differential-Pressure-Switch-for-Air-Filter-Specification-300x124.jpg 300w, https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2023\/01\/A411-Differential-Pressure-Switch-for-Air-Filter-Specification-768x317.jpg 768w, https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2023\/01\/A411-Differential-Pressure-Switch-for-Air-Filter-Specification-600x248.jpg 600w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>","protected":false},"excerpt":{"rendered":"<p>A411 is a differential pressure switch for air filter systems, VAV systems, water heaters, wall-hanging boilers, and so on. Which is available to custom pressure.<\/p>\n<h2>Differential Pressure Switch for Air Filter<\/h2>","protected":false},"featured_media":993,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"product_brand":[],"product_cat":[23],"product_tag":[],"class_list":{"0":"post-990","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-air-pressure-switch","7":"desktop-align-left","8":"tablet-align-left","9":"mobile-align-left","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/product\/990","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/comments?post=990"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/media\/993"}],"wp:attachment":[{"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/media?parent=990"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/product_brand?post=990"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/product_cat?post=990"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.airpressureswitch.com\/de\/wp-json\/wp\/v2\/product_tag?post=990"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}