{"id":1273,"date":"2023-05-05T06:19:07","date_gmt":"2023-05-05T06:19:07","guid":{"rendered":"https:\/\/www.airpressureswitch.com\/?p=1273"},"modified":"2023-05-05T06:40:12","modified_gmt":"2023-05-05T06:40:12","slug":"automatic-water-pressure-switch","status":"publish","type":"post","link":"https:\/\/www.airpressureswitch.com\/ja\/archives\/1273","title":{"rendered":"\u30d6\u30fc\u30b9\u30bf\u30fc\u30dd\u30f3\u30d7\u81ea\u52d5\u6c34\u5727\u30b9\u30a4\u30c3\u30c1"},"content":{"rendered":"<p><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"0\" data-group=\"0-0\">The booster pump<a href=\"https:\/\/www.airpressureswitch.com\/ja\/%e6%b0%b4%e5%9c%a7%e3%82%b9%e3%82%a4%e3%83%83%e3%83%81\/\"> automatic water pressure switch<\/a> is a kind of control pump electrical component, it can sense the change of water pressure and through the control, circuit start or stop the pump.<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"1\" data-group=\"0-1\"> Booster pump automatic water pressure switch is widely used in domestic water supply systems, industrial water treatment systems, and other fields.<\/span><\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-1275\" src=\"https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2023\/05\/\u589e\u538b\u6cf5\u6c34\u538b\u5f00\u5173-1000X482.jpg\" alt=\"\u6c34\u5727\u30b9\u30a4\u30c3\u30c1\" width=\"1000\" height=\"482\" srcset=\"https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2023\/05\/\u589e\u538b\u6cf5\u6c34\u538b\u5f00\u5173-1000X482.jpg 1000w, https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2023\/05\/\u589e\u538b\u6cf5\u6c34\u538b\u5f00\u5173-1000X482-300x145.jpg 300w, https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2023\/05\/\u589e\u538b\u6cf5\u6c34\u538b\u5f00\u5173-1000X482-768x370.jpg 768w, https:\/\/www.airpressureswitch.com\/wp-content\/uploads\/2023\/05\/\u589e\u538b\u6cf5\u6c34\u538b\u5f00\u5173-1000X482-600x289.jpg 600w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p>\n<div id=\"ez-toc-container\" class=\"ez-toc-v2_0_81 counter-hierarchy ez-toc-counter ez-toc-grey ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u76ee\u6b21<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Toggle Table of Content\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u30c8\u30b0\u30eb<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #999;color:#999\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #999;color:#999\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/www.airpressureswitch.com\/ja\/archives\/1273\/#Working_principle_of_water_pressure_switch_of_booster_pump\" >Working principle of water pressure switch of booster pump<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/www.airpressureswitch.com\/ja\/archives\/1273\/#The_booster_pumps_automatic_water_pressure_switch_usually_consists_of_two_parts\" >The booster pump&#8217;s automatic water pressure switch usually consists of two parts:<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/www.airpressureswitch.com\/ja\/archives\/1273\/#The_control_circuit_usually_consists_of_several_key_parts\" >The control circuit usually consists of several key parts:<\/a><\/li><\/ul><\/nav><\/div>\n<h3><span class=\"ez-toc-section\" id=\"Working_principle_of_water_pressure_switch_of_booster_pump\"><\/span>Working principle of water pressure switch of booster pump<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"0\" data-group=\"0-0\">When the booster pump automatic <a href=\"https:\/\/www.airpressureswitch.com\/ja\/%e6%b0%b4%e5%9c%a7%e3%82%b9%e3%82%a4%e3%83%83%e3%83%81\/\">\u6c34\u5727\u30b9\u30a4\u30c3\u30c1<\/a> is connected to a pump and a water source, it first measures the water pressure in the pipe.<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"1\" data-group=\"0-1\"> If the water pressure falls below a preset level, the switch turns on the pump and starts supplying water until the water pressure rises to the preset level, then automatically shuts down the pump and stops supplying water.<\/span><\/p>\n<h3><span class=\"ez-toc-section\" id=\"The_booster_pumps_automatic_water_pressure_switch_usually_consists_of_two_parts\"><\/span>The booster pump&#8217;s automatic water pressure switch usually consists of two parts:<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"0\" data-group=\"0-0\">A sensor to measure water pressure and a control circuit.<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"1\" data-group=\"0-1\"> When the water pressure is lower than the preset value, the sensor detects the water pressure drop signal and sends a signal to the control circuit.<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"2\" data-group=\"0-2\"> After receiving the signal, the control circuit provides the start signal and outputs the electric energy to the motor.<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"3\" data-group=\"0-3\"> Once the water pressure reaches a set point, the sensor stops sending information to the control circuit and the pump stops supplying water.<\/span><\/p>\n<h3><span class=\"ez-toc-section\" id=\"The_control_circuit_usually_consists_of_several_key_parts\"><\/span>The control circuit usually consists of several key parts:<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"0\" data-group=\"0-0\">Sensors, relays, operational amplifiers, comparators, and timers.<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"1\" data-group=\"0-1\"> The functions of these components are water pressure detection, switch control, and set value adjustment.<\/span><span class=\"tgt color_text_0 highlight\" data-section=\"0\" data-sentence=\"2\" data-group=\"0-2\"> The sensor is the most central part, which is responsible for converting water pressure signals into electrical signals that are then sent to other circuit components.<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"3\" data-group=\"0-3\"> If the sensors do not reliably reflect changes in water pressure, the whole system will be out of control.<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"4\" data-group=\"0-4\"> Therefore, in the design of an automatic water pressure switch, it is necessary to choose the appropriate sensor to ensure reliable detection and control.<\/span><\/p>\n<p><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"0\" data-group=\"0-0\">In addition to the design of the control circuit, the appearance and mechanical structure of the booster pump automatic <a href=\"https:\/\/shop9141o982o7514.1688.com\/page\/offerlist_173687048.htm?spm=0.0.wp_pc_common_topnav_category_38229151.0\" target=\"_blank\" rel=\"noopener\">\u6c34\u5727\u30b9\u30a4\u30c3\u30c1<\/a> also need to be carefully designed.<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"1\" data-group=\"0-1\"> The appearance elements include the shell material, size, and form, and the mechanical structure elements include the connection between the sensor and the motor, waterproof performance, and seismic performance.<\/span><span class=\"tgt color_text_0\" data-section=\"0\" data-sentence=\"2\" data-group=\"0-2\"> Mechanical structures are designed to be more demanding than control circuits because they need to support the proper operation of the entire system.<\/span><\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>The booster pump automatic water pressure switch is a kind of control pump electrical component, it can sense the change of water pressure and through the control, circuit start or stop the pump. Booster pump automatic water pressure switch is widely used in domestic water supply systems, industrial water treatment systems, and other fields. Working principle of water pressure switch of booster pump When the booster pump automatic water pressure switch is connected to a pump and a water source, it first measures the water pressure in the pipe. If the water pressure falls below a preset level, the switch turns on the pump and starts supplying water until the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":1274,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"default","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1273","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news"],"_links":{"self":[{"href":"https:\/\/www.airpressureswitch.com\/ja\/wp-json\/wp\/v2\/posts\/1273","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.airpressureswitch.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.airpressureswitch.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.airpressureswitch.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.airpressureswitch.com\/ja\/wp-json\/wp\/v2\/comments?post=1273"}],"version-history":[{"count":2,"href":"https:\/\/www.airpressureswitch.com\/ja\/wp-json\/wp\/v2\/posts\/1273\/revisions"}],"predecessor-version":[{"id":1277,"href":"https:\/\/www.airpressureswitch.com\/ja\/wp-json\/wp\/v2\/posts\/1273\/revisions\/1277"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.airpressureswitch.com\/ja\/wp-json\/wp\/v2\/media\/1274"}],"wp:attachment":[{"href":"https:\/\/www.airpressureswitch.com\/ja\/wp-json\/wp\/v2\/media?parent=1273"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.airpressureswitch.com\/ja\/wp-json\/wp\/v2\/categories?post=1273"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.airpressureswitch.com\/ja\/wp-json\/wp\/v2\/tags?post=1273"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}