Interruptor sensor de flujo de agua Turbina G1/2*2
F11 Water Flow Sensor Description
The F11 water flow sensor switch has 2*G1/2 connectors and its working principle is according to the Karman vortex which is installed in the eddy current plate in the slow flow area. And its rotation speed is proportional to the flow rate generally.
The F11 water flow sensor working principle is according to the Karman vortex which is installed in the eddy current plate in the slow flow area, which has 2*G1/2 connectors and its cable length and type can be customed. Generally, its rotation speed is proportional to the flow rate. That is when the magnetic core rotates the hall effect sensor will detect its speed so that the flow sensor can output the SWFM value.
It can be used in gas boilers, water heaters, water dispensers, etc.
F11 Flow Sensor Features
- It has a competitive price with high precision performance so it will be a perfect product be the alternative sensor for any brand.
- Meanwhile, this water flow sensor also has good electromagnetic compatibility & wide range of working temperatures. So, this lets it has a wide application range in different kinds of devices.
- The F1 series also has a very low-pressure loss when used and its testing components won’t be blocked by the particulate matter easily. So that it can reduce the maintenance cost and increase service life.
- Para más información flow sensor types, Haga clic en el enlace para comprobarlo. Mientras tanto, REGAL es un Experto en la industria de la presión y el flujo, Bienvenido a visitar nuestra página de inicio para obtener más información.
C2-C Level Sensor Specification
| Número de modelo | F11 Water flow sensor |
| Terminal Type | 3-pin standard connector & wire (customizable) |
| Interface type | 2*G1/2 |
| Operating flow interval | 1 L/Min to 30 L/Min |
| Fuerza dieléctrica | 500VAC(<3mA) |
| Operating Voltage | DC 4.75V to DC 5.25V |
| Operating Current | 15mA |
|
Low Output Duty Cycle |
50% |
| Presión de sobrecarga | 12Bar (@40℃) |
| Temperatura de funcionamiento | -15 to 85℃ |
| Service life with loading | 200000 cycles |
| Protection Level | IP20 |