The difference between a pressure switch and a pressure sensor is the output. A pressure switch gives an on/off contact when pressure reaches a set point. A pressure sensor gives a continuous signal proportional to pressure. The two are often confused because both measure pressure, but they solve different control problems.
Side-by-side comparison
| Property | Pressure switch | Pressure sensor |
|---|---|---|
| Output | Dry contact, open or closed | Analogue or digital signal proportional to pressure |
| Information | Trip point only | Continuous pressure reading |
| Typical use | Safety interlocks, pump start/stop, alarms | Measurement, display, modulation, trend logging |
| Control system | Can operate a contactor or valve directly | Needs a controller or PLC to interpret the signal |
| Cost | Lower | Higher |
| Safety role | Can be a certified safety device | Only safety-rated if specified and validated as part of a system |
When to use a pressure switch
Use a switch when the system only needs to know whether pressure is above or below a threshold: proving fan airflow before ignition, starting a pump at low pressure, or triggering a low-pressure alarm. A switch is simple, robust and can switch a load directly.
When to use a pressure sensor
Use a sensor when the controller needs the actual pressure value: modulating a fan or pump, displaying pressure to the user, compensating a flow calculation or logging performance over time. A sensor gives more information but requires a control board to act on it.
Can a sensor replace a switch?
Only when the control system provides equivalent safety logic and the replacement is approved for the application. For a boiler air pressure interlock, replacing a certified switch with a sensor and software requires a safety assessment. In most appliances the switch remains the simpler and more reliable safety device.
Using both
Many systems use both: a switch for the safety interlock and a sensor for control and diagnostics. Regal supplies air pressure switches, air pressure sensors and water pressure switches that can be combined in the same appliance.
Frequently asked questions
What is the main difference between a pressure switch and a pressure sensor?
A pressure switch gives an on/off contact at a set point. A pressure sensor gives a continuous electrical signal proportional to pressure.
When should I use a pressure switch?
Use a switch for safety interlocks, pump start/stop control and simple alarms where only a trip point is needed.
When should I use a pressure sensor?
Use a sensor when the control system needs to measure pressure, display it, modulate a fan or pump, or log trend data.
Can a pressure sensor replace a pressure switch?
Only if the control system provides equivalent safety logic and the replacement is approved for the application. A sensor alone does not guarantee the fail-safe behaviour of a certified switch.
Tell us what your controller needs to do and our engineers will recommend a switch, a sensor or a combination. Contact Regal or read the selection guide.