A flow sensor measures the rate at which water moves through a pipe and converts it into an electrical signal for the control board. In gas water heaters and wall-hung boilers the flow sensor is what tells the burner that a tap has been opened, how much water is flowing and how much heat to apply.
How a Hall-effect flow sensor works
Water passes through a small turbine. A magnet in the rotor turns with the flow, and a Hall-effect chip detects each change in magnetic polarity, producing a pulse. The pulse frequency is proportional to flow rate, so the controller can calculate litres per minute from the signal.
Output and signal
Most Regal flow sensors provide a frequency output, typically a square wave whose frequency rises with flow. Some versions add a temperature sensor or a simple switch output for low-flow detection. The control board converts the pulses into flow rate using the sensor’s K-factor.
Typical specifications
| Parameter | Typical value |
|---|---|
| Flow range | 2-30 litres per minute, depending on model |
| Water temperature | Up to 85 °C |
| Water pressure | Up to 18 kg |
| Output | Frequency / pulse, optional temperature or switch output |
| Connection | Threaded or hose connection, model dependent |
How to choose a flow sensor
- Match the flow range to the appliance: a boiler and a coffee machine need very different ranges.
- Confirm the connection size and the space available around the pipe.
- Check the output type expected by the control board.
- Confirm temperature and pressure ratings for the installation point.
- Choose the installation orientation recommended for the model to avoid air pockets.
Installation and troubleshooting
| Symptom | Likely cause | Check |
|---|---|---|
| No signal at low flow | Air in the line or flow below the start-up threshold | Bleed the system, confirm minimum flow |
| Erratic reading | Debris in the rotor or a failing Hall chip | Flush the sensor, inspect the rotor |
| Reading drifts over time | Scale build-up or worn bearings | Descale or replace the sensor |
Regal manufactures flow sensors for water heaters, wall-hung boilers, coffee machines and beverage equipment, and pairs them with water pressure switches where both flow and pressure must be supervised.
Frequently asked questions
How does a Hall-effect flow sensor work?
Water flow turns a rotor fitted with a magnet. A Hall-effect chip detects each magnetic pole change and outputs a pulse, so the output frequency is proportional to flow rate.
What output does a flow sensor provide?
A frequency or pulse output that the control board converts into litres per minute. Some versions add a temperature sensor or a simple switch output.
What flow range is typical?
Regal flow sensors are designed for roughly 2-30 litres per minute, depending on the model and connection size.
What temperature and pressure can it handle?
Typical ratings are up to 85 °C water temperature and 18 kg water pressure. Confirm the exact rating for the selected model before specifying.
How do I choose a flow sensor?
Match the flow range, connection size, output type, media and temperature to the appliance. Also confirm the installation orientation and available space.
Why is my flow sensor reading wrong?
Air bubbles, debris in the rotor, scale, incorrect orientation or a failing Hall chip can distort the reading. Flush the line and check the installation before replacing the sensor.
Send the flow range, connection and control-board input to our engineers through the contact form for a recommended model.