SOLICITE UM ORÇAMENTO GRÁTIS AGORA!
B12-A Interruptor do sensor de nível do tanque de água quente com 2 interfaces de amostragem
The B12-A hot water tank level sensor switch has two sampling interfaces to detect differential pressure, which is suitable for detecting the water level in the solar water heater, and electric water heater storage tank. And through the B12-A, the detection results are not affected by the gas pressure in the water tank.
Hot Water Tank Level Sensor Switch
The B12-A hot water tank level sensor switch can detect the differential pressure because of its 2 sampling interfaces. However, the B1 water level switch series only can detect one water level, if you need more of them, welcome to visit our water level switches & sensors series or contact us to get it.
Meanwhile, the overflow protection function is available, and this is different from the float-type switch, which is safer and more accurate. The design uses a combination of precise spring-leaf pieces and springs and it will improve the performance and service life.
In order to make it easier for your engineers to design parameters, the start water level, reset water level and overflow water level of this product can be set separately. As well as the angle of the pressure connector which can be adjusted to customers’ requirements.
All in all, we not only can produce the hot water tank level sensor switch but also can produce many kinds of flow and pressure products, welcome to visit our product page to see more details, thank you.
Hot Water Tank Level Sensor Switch Specification
| Número do modelo | B2-A Hot Water Tank Level Sensor Switch |
| Circuito | SPST-NO, SPDT, and SPDT+Overflow |
| Meio de trabalho | Air / Water |
| Avaliação | 1-2(3): 10(2.5) @ 125/250 VAC; 1-6: 1(1) @ 125/250 VAC Or 0.1A @24VDC gold plated contact |
| Terminals | 6.3*0.8 mm (#250), 4.8*0.5mm(#187) |
| Priming Level | Range: 50~400mmw.c., tolerance: +/-5mmw.c |
| Reset Level | Range: 20~350mmw.c., tolerance: +/-5mmw.c |
| Flood Level | Range: 150~600mmw.c., tolerance: +/-5mmw.c |
| Overload pressure | 760mmw.c. (7.6 kPa) |
| Temperatura de trabalho | 85℃ max. |
| Tamanho da interface | 5.5mm outer diameter, suitable for 5mm inner diameter hose |
| Instruções de instalação | The diaphragm is in a vertical plane |
| Diaphragm Material | High-performance silica gel, long-term use temperature >150℃. |
| Material da concha | Engineering plastics PA+GF(UL94-V0 fire rating ) |
| Vida Mecânica | 100,000 cycles |
| Vida útil elétrica | Main circuit: 25,000 cycles; Overflow circuit: 5000 cycles |
Produtos relacionados
-
interruptor de nível de água
Interruptor de nível de água BX1 para máquina de lavar roupa e lava-louças
Leia mais -
interruptor de nível de água
Sensor de nível de água alto/baixo com interruptor de 20 a 200 mmCA.
Leia mais -
interruptor de nível de água
Interruptor de nível de água para lavadora com controle de nível duplo B2G
Leia mais -
interruptor de nível de água
Interruptor de pressão de nível de água para máquina de lavar roupa e máquina de lavar louça.
Leia mais